Guangzhou Hengli Stage Lighting Co., Ltd.
Tel: 020-36372792
Fax: 020-36372251
Technical Support: 13660827877
Contacts: Mr. Liang
Business manager: 13660378626
Contacts: Xiaoping
Business manager: 13640836255
Contacts: Miss Lv
E-mail: admin@henglilight.com
Website: crissangel.cn
Addr.: No.10,Xiqi Industrial Zone, Yagang, Baiyun District, Guangzhou
Safety issues in entertainment venues have always been a concern for people. To stop urgently, we simply look at the fire safety issues of basic light sources in large entertainment venues.
The basic light sources in entertainment venues are mainly concentrated in the stage performance area. These lights can be divided into surface light, side light, top light, sky light, ground light, and flowing light. Generally, spotlights, floodlights, and return lights are used. Lamps and chasing lights, power 0.5 kW to 2 kW stage lighting.
Under normal circumstances, these lamps are used when the temperature of the lamps is high, and they are closely spaced with the stage curtains, scenery, sky curtains, side curtains and other decorations. Therefore, they are the focus of fire prevention. In the design and installation of the basic light source, we must pay attention to the following points.
The first precaution is to build and hoist a temporary lighthouse. The construction and metering department of the building shall be required to approve the load capacity and installation method of the load-bearing components. Towering floor lamp racks have to prevent tilting of the lamp frame to the side where the lamp is installed and the operator side.
Second considerations The luminaire shall be installed on a non-combustible pedestal, with a spacing of more than 0.5 m from the flammable textile such as a curtain, and the distance between the front of the luminaire shall be greater than 1.5 m. It is necessary to fully estimate that the distance to be affected by the factors such as curtain lifting, opening and closing, lamp movement, and swing caused by natural air flow, and insulation measures that cannot meet the safety clearance should be adopted. If the curtain is close to the column light, a fixed metal bracket or net cover should be set to block the curtain from approaching the light.
Article 3 Precautions Try to avoid hanging flags, launching ribbons, flying balloons, and other moving objects in the air in the area of ​​lighting devices to prevent these objects from coming into direct contact with high-temperature lamps. Twinings and collisions cause fires.
Article 4 Precautions When there are people or flammable materials under the lamps, baffles made of wire mesh or non-combustible materials shall be installed on the front and cooling holes of the lamps to reduce the damage caused by the explosion of the lamps and the splashing of glass fragments and hot filaments.
In order to avoid the occurrence of some unsafe incidents, for the sake of customers' safety, entertainment venues must pay attention to the installation and decoration of lighting in the interest of the restaurant, but usually the situation mentioned above can be simply prevented. The occurrence of these insecure events.